Grease Trap Requirements
Chandler, AZ
FOG compliance regulations for food service establishments in Chandler, Arizona.
FOG Compliance in Chandler, AZ
Food service establishments in Chandler operate under a combination of federal EPA pretreatment standards, Arizona state plumbing code, and city-level FOG ordinances. Together these rules determine how grease traps must be sized, how often they must be pumped, and what happens when a restaurant falls out of compliance.
Pumping frequency is the compliance rule restaurant owners interact with most often. In Chandler, the rule is: As needed to prevent FOG discharge exceeding 100 mg/L. This aligns with the 90-day US median enforced by most major cities. The city follows the International Plumbing Code (IPC) for trap sizing and installation. Under Section 1003.3.4, which sizes traps by drainage fixture unit counts, grease interceptors installed in Chandler must meet minimum capacity thresholds based on the fixtures connected to them — 3-compartment sinks, dishwashers, pre-rinse stations, wok stoves, and floor drains on the cook line. The local minimum trap size is: Per Chandler sizing worksheet; gravity grease interceptor sized per flow calculations.
Chandler requires a dedicated FOG permit for any food service establishment generating fats, oils, and grease. The annual permit fee is Per City of Chandler Industrial Pretreatment Program requirements. The permit is separate from, and in addition to, the plumbing permit required at installation. Violations carry maximum penalties of Per Chandler City Code Ch. 51-24 enforcement provisions . Fines typically escalate with repeat violations, and severe discharges that cause sanitary sewer overflows can trigger federal Clean Water Act penalties layered on top of local fines.
Chandler enforces the 25 percent rule: grease traps must be pumped before the combined FOG and settled solids reach 25 percent of the trap's total liquid depth. Inspectors measure the depth with a sludge judge or dipstick, typically at surprise visits. Exceeding the threshold at inspection triggers a notice of violation and mandatory emergency pump-out, regardless of the scheduled pumping cycle. Periodic inspections of all FOG treatment devices at FSEs. Establishments must maintain pumping logs, hauler manifests, and inspection reports on-site — missing records is itself a violation in most enforcement actions. Enforcement authority rests with the City of Chandler Industrial Pretreatment Program – Water Quality Division, which handles permit issuance, inspections, and hauler licensing.
For a deeper explanation of the rules this city enforces, read our guides on how grease traps work and the 25/50 pumping rule.
Pumping Requirements
Permits & Enforcement
Complete FOG Regulations
| Minimum Trap Size | Per Chandler sizing worksheet; gravity grease interceptor sized per flow calculations |
|---|---|
| Pumping Frequency | As needed to prevent FOG discharge exceeding 100 mg/L; regular maintenance required |
| 25% Rule | Yes — trap must be pumped when grease and solids reach 25% of capacity |
| Permit Required | Yes |
| Permit Fee | Per City of Chandler Industrial Pretreatment Program requirements |
| Maximum Fine | Per Chandler City Code Ch. 51-24 enforcement provisions |
| Inspections | Periodic inspections of all FOG treatment devices at FSEs |
| Record Keeping | Required — maintain pumping logs and manifests on-site |
| Plumbing Code | International Plumbing Code (IPC) |
| Ordinance Ref. | Chandler City Code Chapter 51-24; Ordinance No. 4503 (Wastewater Pretreatment Program, Nov 2013) |
| Authority | City of Chandler Industrial Pretreatment Program – Water Quality Division |
Additional Notes
FOG vegetable/petroleum discharge limit of 100 mg/L. Records must be retained onsite for 3 years. Chemical additives, enzymes, and bacterial products directly to FOG device prohibited (Ch. 51-24). Gravity Grease Interceptor Sizing Worksheet available from city.
Last verified: — Regulations change frequently. Always verify current requirements with your local wastewater authority or plumbing inspector before making compliance decisions.
Size Your Grease Trap for Chandler
Our free calculator uses IPC code requirements to recommend the right size.
Open CalculatorOther Cities in Arizona
Every 30 days for <100-gal HGI; every 60 days for ...
PhoenixEvery 90 days minimum; more frequently if grease a...
TempeEvery 90 days (quarterly); or when grease/solids r...
TucsonMinimum every 90 days (quarterly). Pumping require...
MesaEvery 90 days or when FOG/solids reach 25% capacit...
GilbertPer 25% rule; regular maintenance required...
GlendaleRegular basis; before FOG/solids exceed 25%...
ScottsdaleRegular basis; varies by restaurant size and food ...