Grease Trap Requirements
Tacoma, WA
FOG compliance regulations for food service establishments in Tacoma, Washington. Serving 1,703 food service establishments.
FOG Compliance in Tacoma, WA
Food service establishments in Tacoma operate under a combination of federal EPA pretreatment standards, Washington state plumbing code, and city-level FOG ordinances. Together these rules determine how grease traps must be sized, how often they must be pumped, and what happens when a restaurant falls out of compliance. The city has approximately 1,703 food service establishments — every one of them subject to the rules summarized below.
Pumping frequency is the compliance rule restaurant owners interact with most often. In Tacoma, the rule is: Must be pumped when grease and solids reach 25% of interceptor capacity. This aligns with the 90-day US median enforced by most major cities. The city follows the Uniform Plumbing Code (UPC) for trap sizing and installation. Under Section 1014, which applies a fixture drainage load formula with a retention time factor, grease interceptors installed in Tacoma must meet minimum capacity thresholds based on the fixtures connected to them — 3-compartment sinks, dishwashers, pre-rinse stations, wok stoves, and floor drains on the cook line. The local minimum trap size is: Sizes referenced in local code: 500, 1000, 75 gallons.
Tacoma enforces the 25 percent rule: grease traps must be pumped before the combined FOG and settled solids reach 25 percent of the trap's total liquid depth. Inspectors measure the depth with a sludge judge or dipstick, typically at surprise visits. Exceeding the threshold at inspection triggers a notice of violation and mandatory emergency pump-out, regardless of the scheduled pumping cycle.
For a deeper explanation of the rules this city enforces, read our guides on how grease traps work and the 25/50 pumping rule.
Pumping Requirements
Permits & Enforcement
Complete FOG Regulations
| Minimum Trap Size | Sizes referenced in local code: 500, 1000, 75 gallons |
|---|---|
| Pumping Frequency | Must be pumped when grease and solids reach 25% of interceptor capacity |
| 25% Rule | Yes — trap must be pumped when grease and solids reach 25% of capacity |
| Permit Required | Contact authority |
| Record Keeping | Check local requirements |
| Plumbing Code | Uniform Plumbing Code (UPC) |
| Ordinance Ref. | Chapter 12.08.060; section 301.2; section 702.1; Chapter 7; section 702.1 |
Last verified: — Regulations change frequently. Always verify current requirements with your local wastewater authority or plumbing inspector before making compliance decisions.
Contact Information
Environmental Services / Site Development: (253) 591-5760
Official Sources
Size Your Grease Trap for Tacoma
Our free calculator uses UPC code requirements to recommend the right size.
Open CalculatorOther Cities in Washington
Every 90 days (grease traps); Quarterly (grease in...