FOG Compliance in Racine, WI
Food service establishments in Racine operate under a combination of federal EPA pretreatment standards, Wisconsin state plumbing code, and city-level FOG ordinances. Together these rules determine how grease traps must be sized, how often they must be pumped, and what happens when a restaurant falls out of compliance.
Pumping frequency is the compliance rule restaurant owners interact with most often. In Racine, the rule is: Per manufacturer recommendation and use. This aligns with the 90-day US median enforced by most major cities. The city follows the Uniform Plumbing Code (UPC) for trap sizing and installation. Under Section 1014, which applies a fixture drainage load formula with a retention time factor, grease interceptors installed in Racine must meet minimum capacity thresholds based on the fixtures connected to them — 3-compartment sinks, dishwashers, pre-rinse stations, wok stoves, and floor drains on the cook line.
Racine requires a dedicated FOG permit for any food service establishment generating fats, oils, and grease. The permit is separate from, and in addition to, the plumbing permit required at installation.
Racine enforces the 25 percent rule: grease traps must be pumped before the combined FOG and settled solids reach 25 percent of the trap's total liquid depth. Inspectors measure the depth with a sludge judge or dipstick, typically at surprise visits. Exceeding the threshold at inspection triggers a notice of violation and mandatory emergency pump-out, regardless of the scheduled pumping cycle. Establishments must maintain pumping logs, hauler manifests, and inspection reports on-site — missing records is itself a violation in most enforcement actions. Enforcement authority rests with the Racine Wastewater Utility (RWWU); delegated control authority under Wisconsin DNR, which handles permit issuance, inspections, and hauler licensing.
For a deeper explanation of the rules this city enforces, read our guides on how grease traps work and the 25/50 pumping rule.
Pumping Requirements
Permits & Enforcement
Complete FOG Regulations
| Pumping Frequency | Per manufacturer recommendation and use; regular basis required |
|---|---|
| 25% Rule | Yes — trap must be pumped when grease and solids reach 25% of capacity |
| Permit Required | Yes |
| Record Keeping | Required — maintain pumping logs and manifests on-site |
| Plumbing Code | Uniform Plumbing Code (UPC) |
| Ordinance Ref. | Section 98; Section 151 |
| Authority | Racine Wastewater Utility (RWWU); delegated control authority under Wisconsin DNR |
Additional Notes
Municipal Code Sec. 98, 151. Prohibits discharge of fats, wax, grease, or oils and substances solidifying between 32-150°F. No chemical additives permitted. Industrial users pay cost of sampling and inspections. Contact: 262-636-9550.
Last verified: — Regulations change frequently. Always verify current requirements with your local wastewater authority or plumbing inspector before making compliance decisions.
Contact Information
(262) 636-9552
Official Sources
Size Your Grease Trap for Racine
Our free calculator uses UPC code requirements to recommend the right size.
Open CalculatorNeed help with grease trap service in Racine?
If you need cleaning, pumping, installation, sizing, or FOG compliance help in Racine, send the request details. We will review it and can help route it to a relevant provider where available.
Related high-demand FOG requirement guides
These guides are surfaced from Search Console demand and help compare local grease trap rules, pumping schedules, permits and sizing requirements across jurisdictions.
Browse local FOG rules, pumping schedules, permits and fines across covered US cities.
Los Angeles, CA requirementsHigh-demand page for California grease trap sizing and local FOG compliance searches.
North Carolina regulationsStatewide plumbing-code context and city-level FOG compliance links.
Charlotte, NC requirementsLocal pumping, permit and sizing guide for North Carolina restaurants.
Orange, CA requirementsCalifornia city guide with local FOG compliance and interceptor notes.