Grease Trap Requirements
Beloit, WI
FOG compliance regulations for food service establishments in Beloit, Wisconsin.
FOG Compliance in Beloit, WI
Food service establishments in Beloit operate under a combination of federal EPA pretreatment standards, Wisconsin state plumbing code, and city-level FOG ordinances. Together these rules determine how grease traps must be sized, how often they must be pumped, and what happens when a restaurant falls out of compliance.
Pumping frequency is the compliance rule restaurant owners interact with most often. In Beloit, the rule is: Must be pumped when grease and solids reach 25% of interceptor capacity. This aligns with the 90-day US median enforced by most major cities. The city follows the Uniform Plumbing Code (UPC) for trap sizing and installation. Under Section 1014, which applies a fixture drainage load formula with a retention time factor, grease interceptors installed in Beloit must meet minimum capacity thresholds based on the fixtures connected to them — 3-compartment sinks, dishwashers, pre-rinse stations, wok stoves, and floor drains on the cook line.
Beloit enforces the 25 percent rule: grease traps must be pumped before the combined FOG and settled solids reach 25 percent of the trap's total liquid depth. Inspectors measure the depth with a sludge judge or dipstick, typically at surprise visits. Exceeding the threshold at inspection triggers a notice of violation and mandatory emergency pump-out, regardless of the scheduled pumping cycle. Establishments must maintain pumping logs, hauler manifests, and inspection reports on-site — missing records is itself a violation in most enforcement actions.
For a deeper explanation of the rules this city enforces, read our guides on how grease traps work and the 25/50 pumping rule.
Pumping Requirements
Permits & Enforcement
Complete FOG Regulations
| Pumping Frequency | Must be pumped when grease and solids reach 25% of interceptor capacity |
|---|---|
| 25% Rule | Yes — trap must be pumped when grease and solids reach 25% of capacity |
| Permit Required | Contact authority |
| Record Keeping | Required — maintain pumping logs and manifests on-site |
| Plumbing Code | Uniform Plumbing Code (UPC) |
| Ordinance Ref. | ordinance |
Additional Notes
Best Management Practices (BMP) program referenced
Last verified: — Regulations change frequently. Always verify current requirements with your local wastewater authority or plumbing inspector before making compliance decisions.
Contact Information
(608) 364-2929 or Williamsonl@beloitwi.gov
Official Sources
Size Your Grease Trap for Beloit
Our free calculator uses UPC code requirements to recommend the right size.
Open Calculator