Grease Trap Requirements
Roanoke, VA

FOG compliance regulations for food service establishments in Roanoke, Virginia.

FOG Compliance in Roanoke, VA

Food service establishments in Roanoke operate under a combination of federal EPA pretreatment standards, Virginia state plumbing code, and city-level FOG ordinances. Together these rules determine how grease traps must be sized, how often they must be pumped, and what happens when a restaurant falls out of compliance.

Pumping frequency is the compliance rule restaurant owners interact with most often. In Roanoke, the rule is: Per Virginia Plumbing Code and local requirements. This aligns with the 90-day US median enforced by most major cities. The city follows the Uniform Plumbing Code (UPC) for trap sizing and installation. Under Section 1014, which applies a fixture drainage load formula with a retention time factor, grease interceptors installed in Roanoke must meet minimum capacity thresholds based on the fixtures connected to them — 3-compartment sinks, dishwashers, pre-rinse stations, wok stoves, and floor drains on the cook line.

Roanoke requires a dedicated FOG permit for any food service establishment generating fats, oils, and grease. The permit is separate from, and in addition to, the plumbing permit required at installation.

Roanoke enforces the 25 percent rule: grease traps must be pumped before the combined FOG and settled solids reach 25 percent of the trap's total liquid depth. Inspectors measure the depth with a sludge judge or dipstick, typically at surprise visits. Exceeding the threshold at inspection triggers a notice of violation and mandatory emergency pump-out, regardless of the scheduled pumping cycle. Establishments must maintain pumping logs, hauler manifests, and inspection reports on-site — missing records is itself a violation in most enforcement actions. Enforcement authority rests with the Western Virginia Water Authority, which handles permit issuance, inspections, and hauler licensing.

For a deeper explanation of the rules this city enforces, read our guides on how grease traps work and the 25/50 pumping rule.

Per Virginia Plumbing Code and
Pumping Freq.
Required
Permit
Yes
25% Rule
UPC
Code Base

Pumping Requirements

Frequency Per Virginia Plumbing Code and local requirements
25% Rule Applies

Permits & Enforcement

Permit Required Required

Complete FOG Regulations

Pumping Frequency Per Virginia Plumbing Code and local requirements
25% Rule Yes — trap must be pumped when grease and solids reach 25% of capacity
Permit Required Yes
Record Keeping Required — maintain pumping logs and manifests on-site
Plumbing Code Uniform Plumbing Code (UPC)
Ordinance Ref. Section 802.4; Section 1001; Chapter 10; Section 1002
Authority Western Virginia Water Authority

Additional Notes

Automatic Grease Removal Units (AGRU) mentioned as option. AGRUs accepted as alternative. Virginia Plumbing Code Chapter 10 applies.

Last verified: — Regulations change frequently. Always verify current requirements with your local wastewater authority or plumbing inspector before making compliance decisions.

Contact Information

Phone (540) 853-5700
Email info@westernvawater.org

Western Virginia Water Authority: (540) 853-5700 or info@westernvawater.org

Official Sources

Size Your Grease Trap for Roanoke

Our free calculator uses UPC code requirements to recommend the right size.

Open Calculator

Other Cities in Virginia

Alexandria Arlington

Per manufacturer recommendations and BMP; typicall...

Hampton

Minimum every 90 days (quarterly) or when 25% capa...

Lynchburg

weekly; or when grease/solids reach 25% of capacit...

Norfolk

Minimum quarterly (4x/year) or when 25% full...

Pulaski

Minimum every 4 months or when 25% capacity reache...

Richmond

Monthly...

Salem