Grease Trap Requirements
Orem, UT

FOG compliance regulations for food service establishments in Orem, Utah.

FOG Compliance in Orem, UT

Food service establishments in Orem operate under a combination of federal EPA pretreatment standards, Utah state plumbing code, and city-level FOG ordinances. Together these rules determine how grease traps must be sized, how often they must be pumped, and what happens when a restaurant falls out of compliance.

Pumping frequency is the compliance rule restaurant owners interact with most often. In Orem, the rule is: Every 90 days or when 25% full. This aligns with the 90-day US median enforced by most major cities. The city follows the Uniform Plumbing Code (UPC) for trap sizing and installation. Under Section 1014, which applies a fixture drainage load formula with a retention time factor, grease interceptors installed in Orem must meet minimum capacity thresholds based on the fixtures connected to them — 3-compartment sinks, dishwashers, pre-rinse stations, wok stoves, and floor drains on the cook line.

Orem requires a dedicated FOG permit for any food service establishment generating fats, oils, and grease. The permit is separate from, and in addition to, the plumbing permit required at installation.

Orem enforces the 25 percent rule: grease traps must be pumped before the combined FOG and settled solids reach 25 percent of the trap's total liquid depth. Inspectors measure the depth with a sludge judge or dipstick, typically at surprise visits. Exceeding the threshold at inspection triggers a notice of violation and mandatory emergency pump-out, regardless of the scheduled pumping cycle. Establishments must maintain pumping logs, hauler manifests, and inspection reports on-site — missing records is itself a violation in most enforcement actions. Enforcement authority rests with the City of Orem Public Works, which handles permit issuance, inspections, and hauler licensing.

For a deeper explanation of the rules this city enforces, read our guides on how grease traps work and the 25/50 pumping rule.

Every 90 days or when 25% full
Pumping Freq.
Required
Permit
Yes
25% Rule
UPC
Code Base

Pumping Requirements

Frequency Every 90 days or when 25% full
25% Rule Applies

Permits & Enforcement

Permit Required Required

Complete FOG Regulations

Pumping Frequency Every 90 days or when 25% full
25% Rule Yes — trap must be pumped when grease and solids reach 25% of capacity
Permit Required Yes
Record Keeping Required — maintain pumping logs and manifests on-site
Plumbing Code Uniform Plumbing Code (UPC)
Ordinance Ref. Section 802.3.3; Section 1001; Chapter 10; Section 1002
Authority City of Orem Public Works

Additional Notes

Automatic Grease Removal Units (AGRU) mentioned as option. Utah IPC adoption applies. AGRUs accepted as alternative.

Last verified: — Regulations change frequently. Always verify current requirements with your local wastewater authority or plumbing inspector before making compliance decisions.

Contact Information

Phone 801.229.7500
Email publicworks@orem.org

Public Works: 801.229.7500 or publicworks@orem.org

Official Sources

Size Your Grease Trap for Orem

Our free calculator uses UPC code requirements to recommend the right size.

Open Calculator

Other Cities in Utah

Ogden

Every 90 days or when FOG reaches 25% of design ca...

Salt Lake City