Grease Trap Requirements
Murfreesboro, TN

FOG compliance regulations for food service establishments in Murfreesboro, Tennessee.

FOG Compliance in Murfreesboro, TN

Food service establishments in Murfreesboro operate under a combination of federal EPA pretreatment standards, Tennessee state plumbing code, and city-level FOG ordinances. Together these rules determine how grease traps must be sized, how often they must be pumped, and what happens when a restaurant falls out of compliance.

Pumping frequency is the compliance rule restaurant owners interact with most often. In Murfreesboro, the rule is: Every 90 days (quarterly). This aligns with the 90-day US median enforced by most major cities. The city follows the International Plumbing Code (IPC) for trap sizing and installation. Under Section 1003.3.4, which sizes traps by drainage fixture unit counts, grease interceptors installed in Murfreesboro must meet minimum capacity thresholds based on the fixtures connected to them — 3-compartment sinks, dishwashers, pre-rinse stations, wok stoves, and floor drains on the cook line. The local minimum trap size is: Sizes referenced in local code: 50, 35, 75 gallons.

Murfreesboro enforces the 25 percent rule: grease traps must be pumped before the combined FOG and settled solids reach 25 percent of the trap's total liquid depth. Inspectors measure the depth with a sludge judge or dipstick, typically at surprise visits. Exceeding the threshold at inspection triggers a notice of violation and mandatory emergency pump-out, regardless of the scheduled pumping cycle. Establishments must maintain pumping logs, hauler manifests, and inspection reports on-site — missing records is itself a violation in most enforcement actions.

For a deeper explanation of the rules this city enforces, read our guides on how grease traps work and the 25/50 pumping rule.

Every 90 days (quarterly)
Pumping Freq.
Check locally
Permit
Yes
25% Rule
IPC
Code Base

Pumping Requirements

Frequency Every 90 days (quarterly); or when grease/solids reach 25% of capacity
25% Rule Applies

Permits & Enforcement

Permit Required Contact authority

Complete FOG Regulations

Minimum Trap Size Sizes referenced in local code: 50, 35, 75 gallons
Pumping Frequency Every 90 days (quarterly); or when grease/solids reach 25% of capacity
25% Rule Yes — trap must be pumped when grease and solids reach 25% of capacity
Permit Required Contact authority
Record Keeping Required — maintain pumping logs and manifests on-site
Plumbing Code International Plumbing Code (IPC)
Ordinance Ref. section; Chapter 33; Section 33; Section 33-36

Additional Notes

Best Management Practices (BMP) program referenced. Automatic Grease Removal Units (AGRU) mentioned as option

Last verified: — Regulations change frequently. Always verify current requirements with your local wastewater authority or plumbing inspector before making compliance decisions.

Contact Information

Phone (615) 890-0862

City of Murfreesboro Water Resources: (615) 890-0862

Official Sources

Size Your Grease Trap for Murfreesboro

Our free calculator uses IPC code requirements to recommend the right size.

Open Calculator

Other Cities in Tennessee

Chattanooga

Must be pumped when grease and solids reach 25% of...

Jackson

monthly...

Johnson City

Must be pumped when grease and solids reach 25% of...

Knoxville

Minimum quarterly; frequency determined by KUB ins...

Memphis

Every 90 days minimum; or when FOG and solids reac...

Nashville

At minimum every 90 days; Metro Water Services may...

Clarksville